ACCS 3350 255TB-A 4TDD 4X 1GBE 4X 25-10GBE ESSEN INSTL BNDL INIT
Technical Specification | Access 3350 Appliance system | |
---|---|---|
Number of compute nodes per 3350 Appliance system | 2 | |
Processor model (each compute node) |
|
|
CPU speed | 2.2 GHz (Turbo: 3.2 GHz) | |
Cores (each compute node) | 20 (10 per processor) | |
Smart Cache (each compute node) | 13.75 MB | |
System memory (per compute node) | Base memory capacity: 384GB
Memory type: DDR4 LRDIMM Configuration: 6 x 64GB LRDIMM modules Operating voltage: 1.2V Configured clock speed: 2400MHz Maximum clock speed: up to 3200MHz |
|
Usable AdvancedDisk storage capacity (TB) | Usable AdvancedDisk storage capacity: up to 2544 TiB (2800 TB) | |
SAS RAID mezzanine card | Yes | |
SAS RAID PCIe card installed in a appliance compute node PCIe riser assembly | No | |
RAID levels |
RAID1 (mirroring) and RAID6 (block level striping with double distributed parity) are used as follows:
Note: RAID levels are generated using an onboard Intel RMSHC080 RAID controller that is installed in each 3350 Appliance compute node. |
|
Maximum number of storage shelves | 4
Note: Depending on the storage configuration purchased, the maximum number of storage shelves consists of one required 5U84 Primary Storage Shelves and up to three optional 5U84 Expansion Storage Shelves. |
|
I/O Ports | Two 12Gb SAS3 host bus adapters
(PCIe-based) |
Used to connect both of the Access 3350 Appliance compute nodes to the 5U84 Primary Storage Shelf |
10/25GB Ethernet PCIe-based network interface card | Two ports | |
1Gb Ethernet ports | Four on-board ports | |
Rack information | 19″ EIA standard | |
Dimensions (IEC rack compliant) |
Each Appliance compute node
See 3350 Appliance compute node technical specifications. 5U84 Primary Storage Shelf / 5U84 Expansion Storage Shelf
Note: The Veritas 5U84 Primary Storage Shelf and the 5U84 Expansion Storage Shelf are longer than what a standard IEC-compliant rack normally supports. Due to the additional length, the rack-based PDU hardware may need to be installed on the outside of the rack to accommodate the storage shelves. |
|
Maximum weight | Each Appliance compute node: 23.26 kg (51.28 lbs)
5U84 Primary Storage Shelf: 128 kg (282 lbs) with drives and rail kit 5U84 Expansion Storage Shelf: 128 kg (282 lbs) with drives and rail kit |
|
Typical power consumption |
Each Appliance compute node
Each storage shelf
|
|
Maximum power consumption |
Each Appliance compute node
Each storage shelf
|
|
Typical power consumption with a maximum of four external storage shelves | 4,200 watts (two servers per cluster) | |
Maximum power consumption with a maximum of four external storage shelves | 6,200 watts (two servers per cluster)
(500 watts maximum per server) |
|
AC power requirements |
Each compute node:
Each storage shelf:
|
|
AC power cable |
Each compute node:
See Power cables. Storage shelf:
See Power cables. |
|
Power Factor | > 90% | |
System cooling requirement (heat dissipation)
(Appliance with maximum storage shelves attached) |
Typical
Maximum
|
|
Operating voltage | 200 – 240 VAC | |
AC Frequency range | 50/60 Hz | |
Power conversion efficiency | Each Appliance compute node: 90% +
5U84 Primary/Expansion Storage Shelf: 89% + |
|
Acoustic noise |
Each Appliance compute node
5U84 Primary/Expansion Storage Shelf
|
Reviews