3-PHASE PDU MONITORED 208/240V 24 C13 6 C19 L21-30P 10KW 0U TAA

$1,075.27

Tripp Lite PDU 3-Phase Monitored 24 C13 6 C19 208/240V L21-30P 10kW 0U TAA – Monitored – NEMA L21-30P – 24 x IEC 60320 C13, 6 x IEC 60320 C19 – 230 V AC – Network (RJ-45) – 0U – Vertical/Toolless – Rack-mountable – TAA Compliant

SKU: PDU3EVNR6L2130 UPC: 0037332242228 Brand: Tripp Lite Condition: New Categories: , ,

Description

Tripp Lite PDU 3-Phase Monitored 24 C13 6 C19 208/240V L21-30P 10kW 0U TAA – Monitored – NEMA L21-30P – 24 x IEC 60320 C13, 6 x IEC 60320 C19 – 230 V AC – Network (RJ-45) – 0U – Vertical/Toolless – Rack-mountable – TAA Compliant

10kW 3-Phase PDU Distributes and Monitors Network-Grade Power

This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the PDU3EVNR6L2130 features 24 C13 and six C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged.

Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time

Not only can you remotely monitor voltage and frequency, but the PDU3EVNR6L2130 also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP.

Color Touchscreen LCD Gives You Important Data at a Glance

An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack

The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a NEMA L21-30P 208/240V input connects the PDU to a compatible AC power source, generator or protected UPS.

TAA-Compliant for GSA Schedule Purchases

The PDU3EVNR6L2130 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Additional information

Product Type

PDU

Product Model

PDU3EVNR6L2130

Receptacle Detail

24 x IEC 60320 C13

Depth

2.9"

Width

2.2"

Height

70"

Mount Type

Rack-mountable

Weight (Approximate)

14.22 lb

Environmental Certification

RoHS

Environmentally Friendly

Yes

Country of Origin

Taiwan

Package Contents

PDU3EVNR6L2130 30-Outlets PDU Built-in LX Platform interface Configuration cable (30) Plug-lock insert sleeves Rack-mounting hardware Spare mounting buttons PDUMVROTATEBRKT mounting bracket accessory Owner's manual

Management

HTTP HTTPS SMTP FTP DHCP NTP SNMP: v1 v2 v3 v2c

Network (RJ-45)

Yes

Marketing Information

10kW 3-Phase PDU Distributes and Monitors Network-Grade Power This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the PDU3EVNR6L2130 features 24 C13 and six C19 208/240V outlets in three breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged. Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time Not only can you remotely monitor voltage and frequency, but the PDU3EVNR6L2130 also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices. Built-In LX Platform Network Management Card Allows Remote Access 24/7 The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP. Color Touchscreen LCD Gives You Important Data at a Glance An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert® Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity. Easy to Install Vertically in an EIA-Standard 19 in. Rack The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a NEMA L21-30P 208/240V input connects the PDU to a compatible AC power source, generator or protected UPS. TAA-Compliant for GSA Schedule Purchases The PDU3EVNR6L2130 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Product Name

PDU3EVNR6L2130 30-Outlets PDU

Manufacturer

Tripp Lite by Eaton

Input Voltage

230 V AC

Manufacturer Website Address

http://www.tripplite.com

Manufacturer Part Number

PDU3EVNR6L2130

Power Rating (Watt)

10 kW

Mounting Orientation

Vertical/Toolless

PDU Type

Monitored

TAA Compliant

Yes

Receptacle Type

IEC 60320 C19

Phase

Three Phase

Plug/Connector Type

NEMA L21-30P

Brand Name

Tripp Lite

Rack Height

0U

Protection Type

Overload Protection

Input Current

30 A

Output Voltage

240 V AC

Plug/Connector Detail

1 x NEMA L21-30P