Previous
Previous Product Image

UPS SMART 1050VA 900WAVR LCD USB BATTERY BACK UP DESKTOP TOWER

$267.43
Next

BATTERY PACK 3-PHASE UPS 120VDC 2 CABINET NO BATTERIES

$14,410.50
Next Product Image

EDGEREADY MICRO DATA CENTER 40U 3000VA UPS PDU 42U RACK 120V

$4,250.43

Tripp Lite EdgeReadyâ„¢ Micro Data Center 40U 3 kVA UPS Network Management and PDU 120V Assembled/Tested Unit

SKU: MDA1F40UPX00000 UPC: 0037332247131 Brand: Tripp Lite Condition: New Categories: , ,

Description

Tripp Lite EdgeReadyâ„¢ Micro Data Center 40U 3 kVA UPS Network Management and PDU 120V Assembled/Tested UnitShip in Days, Not Weeks

Tripp Lite’s EdgeReady™ micro data centers ship three business days after order receipt, assembled and tested. 40 base configurations are available for immediate order, or Tripp Lite’s solutions team can customize every aspect of any base configuration to match your specific application. Customized solutions ship in as little as five business days.

Protect Edge Computing

Convenient and cost-effective EdgeReady™ micro data centers protect edge computing servers, storage and network hardware in locations where dedicated IT space is unavailable. Sites like branch offices, banks, retail locations, cell towers and factories often have little or no access to on-site IT staff, but they still require exceptional uptime for edge computing. Micro data centers require minimal space and support, yet provide availability comparable to a traditional data center.

Integrate Key Components

Base configurations combine a rack enclosure, UPS system, network management card, environmental/security sensor, power distribution unit (PDU), downloadable network management software, passive cooling and optional active cooling.

Save Time and Reduce Costs

Preconfigured IT infrastructure accelerates and standardizes installations for quick, easy, repeatable deployments and maintenance. Experienced solution experts design, validate, assemble and test solutions in a controlled environment to simplify orders, prevent configuration errors and reduce field costs. Reinforced shock pallets and torqued fittings stabilize shipment and support re-shipment from an intermediary configuration site.

Target Specific Applications

Tripp Lite offers 40 base configurations, and you can customize any model for your application. Options include active cooling, extended runtime, KVM switches, console servers, added security, airflow management, cable managers, power cords, network cables and patch panels. You can also upgrade the base PDU, rack or UPS.

Power Critical Systems

A SmartOnline® UPS system provides voltage- and frequency-independent (VFI) operation, expandable battery backup, zero transfer time and pure sine wave output. On-line double conversion isolates equipment from blackouts, brownouts, overvoltages, transients, surges, line noise, harmonic distortion, electrical impulses and frequency variations to prevent damage, downtime and data loss. Included battery capacity outlasts most power problems, and optional battery packs increase runtime. A metered PDU plugs into the UPS system to provide numerous outlets and digital current metering. An optional switched PDU adds remote current monitoring, threshold notifications and outlet control.

Manage from Any Location

A network management card provides monitoring, control and alerts via SNMP, Web, SSH or telnet. An environmental sensor monitors temperature, humidity and digital inputs. Free PowerAlert® Network Management System manages up to 250 units, or you can use your SNMP-compatible software of choice. Additional options include network-accessible KVM switches and console servers with fail-safe remote access.

Secure Equipment and Data

A PCI-compliant steel cabinet with EIA-standard mounting rails secures rack-mounted IT equipment. Doors and side panels lock to prevent unauthorized access, and an optional door-monitoring kit enables remote intrusion detection.

Additional information

Product Type

UPS/Network Management/PDU Kit

Brand Name

Tripp Lite

Country of Origin

China

Manufacturer Part Number

MDA1F40UPX00000

Manufacturer Website Address

http://www.tripplite.com

Manufacturer

Tripp Lite by Eaton

Product Model

MDA1F40UPX00000

Product Name

MDA1F40UPX00000 UPS/Network Management/PDU Kit

Marketing Information

Ship in Days, Not Weeks Tripp Lite's EdgeReady™ micro data centers ship three business days after order receipt, assembled and tested. 40 base configurations are available for immediate order, or Tripp Lite's solutions team can customize every aspect of any base configuration to match your specific application. Customized solutions ship in as little as five business days. Protect Edge Computing Convenient and cost-effective EdgeReady™ micro data centers protect edge computing servers, storage and network hardware in locations where dedicated IT space is unavailable. Sites like branch offices, banks, retail locations, cell towers and factories often have little or no access to on-site IT staff, but they still require exceptional uptime for edge computing. Micro data centers require minimal space and support, yet provide availability comparable to a traditional data center. Integrate Key Components Base configurations combine a rack enclosure, UPS system, network management card, environmental/security sensor, power distribution unit (PDU), downloadable network management software, passive cooling and optional active cooling. Save Time and Reduce Costs Preconfigured IT infrastructure accelerates and standardizes installations for quick, easy, repeatable deployments and maintenance. Experienced solution experts design, validate, assemble and test solutions in a controlled environment to simplify orders, prevent configuration errors and reduce field costs. Reinforced shock pallets and torqued fittings stabilize shipment and support re-shipment from an intermediary configuration site. Target Specific Applications Tripp Lite offers 40 base configurations, and you can customize any model for your application. Options include active cooling, extended runtime, KVM switches, console servers, added security, airflow management, cable managers, power cords, network cables and patch panels. You can also upgrade the base PDU, rack or UPS. Power Critical Systems A SmartOnline® UPS system provides voltage- and frequency-independent (VFI) operation, expandable battery backup, zero transfer time and pure sine wave output. On-line double conversion isolates equipment from blackouts, brownouts, overvoltages, transients, surges, line noise, harmonic distortion, electrical impulses and frequency variations to prevent damage, downtime and data loss. Included battery capacity outlasts most power problems, and optional battery packs increase runtime. A metered PDU plugs into the UPS system to provide numerous outlets and digital current metering. An optional switched PDU adds remote current monitoring, threshold notifications and outlet control. Manage from Any Location A network management card provides monitoring, control and alerts via SNMP, Web, SSH or telnet. An environmental sensor monitors temperature, humidity and digital inputs. Free PowerAlert® Network Management System manages up to 250 units, or you can use your SNMP-compatible software of choice. Additional options include network-accessible KVM switches and console servers with fail-safe remote access. Secure Equipment and Data A PCI-compliant steel cabinet with EIA-standard mounting rails secures rack-mounted IT equipment. Doors and side panels lock to prevent unauthorized access, and an optional door-monitoring kit enables remote intrusion detection.

Additional Information

OVERVIEWUPC Code 037332247131 Rack Type Floor-Standing UPS Type On-Line PDU TypeMetered POWEROutput Power Capacity (kVA) 3 Output Power Capacity (Amps) 22.5 Output Power Capacity (kW) 2.7 Site Power Required 120V, 30A, 50/60 Hz Site Outlet Required NEMA L5-30R COOLINGCooling Type Passive Cooling Type Details See Components List for active cooling options OUTPUTOutput AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Usable Outlets (UPS and PDU) (4) 5-15R; (28) 5-15/20R INPUTNominal Input Voltage(s) Supported 100V AC; 110V AC; 115V AC; 120V AC; 127V AC Input Phase Single-Phase Input Plug Type NEMA L5-30P BATTERYFull Load Runtime (min.) 4.1 min. Half Load Runtime (min.) 11 min. Expandable Runtime Yes PHYSICALMaximum Device Depth (in.) 37 Rack Height 42U Usable Rack Space 40U Total Weight Capacity (lbs.) 3000 Usable Weight Capacity (lbs.) 2633 Unit Dimensions (hwd / in.) 78.5 x 23.63 x 43 Shipping Form Factor Assembled/Tested Unit Unit Weight (lbs.) 367 ENVIRONMENTALEnvironmental Sensor E2MTHDI COMMUNICATIONSNetwork Management Cards WEBCARDLX SPECIAL FEATURESHigh Availability UPS Features On-Line (VFI) Operation; Auto Bypass; Battery Backup; Hot swappable batteries Acoustic Noise Suppression Yes

Package Contents

SR42UB Premium Rack Enclosure SU3000RTXLCD2U UPS System WEBCARDLX Network Management Card E2MTHDI Environmental Sensor PDUMV30 Metered PDU Owner's Manuals

Environmentally Friendly

Yes

Environmental Certification

RoHS