M14 CHILLEDDOOR 48U600MM 46-60KW FULL PLC LOGIC/CTRL TOP

$13,495.06

Motivair ChilledDoor Rack Cooling System – Rack-mountable – IT – 60 kW – Liquid Cooler – 48U – 230 V AC – 7 A

SKU: MCD-M14-48U600-TF UPC: Brand: Motivair Condition: New Categories: , ,

Description

Motivair ChilledDoor Rack Cooling System – Rack-mountable – IT – 60 kW – Liquid Cooler – 48U – 230 V AC – 7 AThe Motivair ChilledDoor® Rack Cooling System is an active rear door heat exchanger that is mounted directly to the rear of any standard server rack. It is capable of removing up to 75kW per rack using warmer water temperatures. Multiple variables are constantly monitored and adjusted to ensure that the ChilledDoor® is actively adjusting to conditions inside the rack. The Motivair ChilledDoor® system operates using cool water above the data center dew point which eliminates the possibility of condensation near the servers. Active heat removal and rack monitoring creates reliable cooling and a “heat neutral” white space. The result is significantly increased data center efficien­cies. If central chilled water is available but below room dew point, a Coolant Distribution Unit (CDU) is available. See CDU collateral for further detail and application.

Additional information

Application/Usage

IT

Product Type

Airflow Cooling System

Form Factor

Rack-mountable

Brand Name

Motivair

Cooler Type

Liquid Cooler

Compatible Rack Height

48U

Manufacturer Part Number

MCD-M14-48U600-TF

Manufacturer Website Address

http://www.motivaircorp.com

Manufacturer

Motivair Corporation

Product Name

ChilledDoor Rack Cooling System

Product Line

Chilled Door

Marketing Information

The Motivair ChilledDoor® Rack Cooling System is an active rear door heat exchanger that is mounted directly to the rear of any standard server rack. It is capable of removing up to 75kW per rack using warmer water temperatures. Multiple variables are constantly monitored and adjusted to ensure that the ChilledDoor® is actively adjusting to conditions inside the rack. The Motivair ChilledDoor® system operates using cool water above the data center dew point which eliminates the possibility of condensation near the servers. Active heat removal and rack monitoring creates reliable cooling and a "heat neutral" white space. The result is significantly increased data center efficien­cies. If central chilled water is available but below room dew point, a Coolant Distribution Unit (CDU) is available. See CDU collateral for further detail and application.

Country of Origin

United States

Input Voltage

230 V AC

Input Current

7 A

Cooling Power Consumption

60 kW