PDU 3-PHASE VERTICAL STRIP ATS 208V 17.3KW 42 C13 12 C19 0URM

$738.33

Tripp Lite PDU 3-Phase Vertical Strip ATS 208V 17.3kW 42 C13; 12 C19 0URM – IEC 60320 C19, IEC 60320 C13 – 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC – 17.30 kVA – 0U – Vertical Rackmount

SKU: PDU3V602D354A UPC: 0037332192486 Brand: Tripp Lite Condition: New Categories: , ,

Description

Tripp Lite PDU 3-Phase Vertical Strip ATS 208V 17.3kW 42 C13; 12 C19 0URM – IEC 60320 C19, IEC 60320 C13 – 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC – 17.30 kVA – 0U – Vertical Rackmount

The PDU3V602D354A 17.3kW 3-Phase Vertical PDU Outlet Strip is a required accessory option for Tripp Lite’s PDU360AT6G60 and other 3-phase ATS PDUs that specify compatibility with this model. It’s recommended for high-density equipment racks in data centers, server rooms and heavily configured equipment racks.

When used with the PDU360AT6G60, the PDU3V602D354A supports up to 17.3kW total output with 27.8A balanced maximum full load per output phase combination (L1-L2, L2-L3, L3-L1) and 13.9A balanced maximum per breakered output load bank (C1-C6).

The 42 C13 and 12 C19 single-phase 208V outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. Dual 2.5-foot power cords, each with a special eight-position plug, connect directly to the PDU’s rear receptacles.

The PDU3V602D354A’s rugged all-metal housing mounts in compatible racks with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.

Features

Required Accessory for Select Tripp Lite ATS PDUs

  • Compatible with PDU360AT6G60 and other select Tripp Lite 3-phase ATS PDUs
  • Recommended for high-density equipment racks in data centers and server rooms
  • Saves rack space, improves airflow and reduces cord clutter by locating outlets closer to connected devices
  • Supports up to 17.3kW total output with 27.8A maximum per output phase combination and 13.9A max per breakered output load bank
  • Heavy-duty 2.5 ft. power cords with proprietary 8-position plugs connect to ATS PDU

42 C13 and 12 C19 Interlaced 208V Outlets

  • Single-phase outlets help balance loads by spreading connections across phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack
  • Numbered and color-coded for easy ID of connected devices and which phase combination powers them
  • 20A double-pole magnetic circuit breakers protect against overload

Installs Easily in 0U of Rack Space

  • Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks
  • Preinstalled grounding lug for connecting devices that require chassis ground
  • Heavy-duty all-metal housing provides durability in demanding rack environments

Additional information

Product Type

PDU

Manufacturer

Tripp Lite by Eaton

Width

4"

Height

70"

Mount Type

Rack-mountable

Weight (Approximate)

19 lb

Environmental Certification

RoHS

Environmentally Friendly

Yes

Country of Origin

Taiwan

Marketing Information

The PDU3V602D354A 17.3kW 3-Phase Vertical PDU Outlet Strip is a required accessory option for Tripp Lite's PDU360AT6G60 and other 3-phase ATS PDUs that specify compatibility with this model. It's recommended for high-density equipment racks in data centers, server rooms and heavily configured equipment racks.When used with the PDU360AT6G60, the PDU3V602D354A supports up to 17.3kW total output with 27.8A balanced maximum full load per output phase combination (L1-L2, L2-L3, L3-L1) and 13.9A balanced maximum per breakered output load bank (C1-C6).The 42 C13 and 12 C19 single-phase 208V outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. Dual 2.5-foot power cords, each with a special eight-position plug, connect directly to the PDU's rear receptacles. The PDU3V602D354A's rugged all-metal housing mounts in compatible racks with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack. Features Required Accessory for Select Tripp Lite ATS PDUs Compatible with PDU360AT6G60 and other select Tripp Lite 3-phase ATS PDUs Recommended for high-density equipment racks in data centers and server rooms Saves rack space, improves airflow and reduces cord clutter by locating outlets closer to connected devices Supports up to 17.3kW total output with 27.8A maximum per output phase combination and 13.9A max per breakered output load bank Heavy-duty 2.5 ft. power cords with proprietary 8-position plugs connect to ATS PDU 42 C13 and 12 C19 Interlaced 208V Outlets Single-phase outlets help balance loads by spreading connections across phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack Numbered and color-coded for easy ID of connected devices and which phase combination powers them 20A double-pole magnetic circuit breakers protect against overload Installs Easily in 0U of Rack Space Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks Preinstalled grounding lug for connecting devices that require chassis ground Heavy-duty all-metal housing provides durability in demanding rack environments

Product Name

PDU3V602D354A 54-Outlet PDU

Product Model

PDU3V602D354A

Manufacturer Website Address

http://www.tripplite.com

Input Voltage

230 V AC

Manufacturer Part Number

PDU3V602D354A

Power Rating (Watt)

17.30 kW

Mounting Orientation

Vertical

TAA Compliant

Yes

Receptacle Type

IEC 60320 C13

Phase

Three Phase

Input Voltage Range

200 V AC – 240 V AC

Brand Name

Tripp Lite

Rack Height

0U

Input Current

48 A

Output Voltage

200 V AC

Depth

2.2"