Free Shipping
Free Returns
Easy Payments
Sign up For our Blog
Trade in Welcome
Buy or Lease
Previous
Previous Product Image

UPS REPLACEMENT BATTERY 2 SETS OF 8 192VDC SMART ONLINE

$812.94
Next

SMART ONLINE UPS 8KVA 208 &120V 7200W 8URM USB DB9 HOT SWAP 1 TF

$5,217.00
Next Product Image

PDU ATS / METERED 120V 1.44KW 15A 8 5-15R DUAL 5-15P 12FT CORDS

$303.23

Tripp Lite PDU ATS / Metered 120V 1.44kW 15A 8 5-15R Dual 5-15P 12ft Cords – Metered Auto Transfer Switch – NEMA 5-15P – 8 x NEMA 5-15R – 120 V AC – 1U – Horizontal – Rack-mountable, Wall-mountable – TAA Compliant

SKU: PDUMH15ATS UPC: 0037332261366 Brand: Tripp Lite Condition: New Categories: , ,

Description

Tripp Lite PDU ATS / Metered 120V 1.44kW 15A 8 5-15R Dual 5-15P 12ft Cords – Metered Auto Transfer Switch – NEMA 5-15P – 8 x NEMA 5-15R – 120 V AC – 1U – Horizontal – Rack-mountable, Wall-mountable – TAA Compliant

Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH15ATS features eight NEMA 5-15R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA 5-15P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds
Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.

Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases
The PDUMH15ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Additional information

Product Type

PDU

Manufacturer

Tripp Lite by Eaton

Receptacle Detail

8 x NEMA 5-15R

Depth

14.5"

Width

17.5"

Height

1.8"

Mount Type

Wall-mountable

Weight (Approximate)

11 lb

Environmental Certification

RoHS

Environmentally Friendly

Yes

Country of Origin

Taiwan

Package Contents

8-Outlets PDU Detachable C13 To NEMA 5-15P Secondary Input Cord, 12 Ft. (3.7 m) Rack-Mounting Hardware Cord Retention Kit Owner's Manual

Marketing Information

Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH15ATS features eight NEMA 5-15R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA 5-15P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Switches from Primary to Secondary Power Source in MillisecondsAutomatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source. Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter. TAA-Compliant for GSA Schedule PurchasesThe PDUMH15ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Product Name

8-Outlets PDU

Manufacturer Website Address

http://www.tripplite.com

Input Voltage

120 V AC

Manufacturer Part Number

PDUMH15ATS

Power Rating (Watt)

1520 W

Mounting Orientation

Horizontal

PDU Type

Metered Auto Transfer Switch

TAA Compliant

Yes

Receptacle Type

NEMA 5-15R

Phase

Single Phase

Plug/Connector Type

NEMA 5-15P

Brand Name

Tripp Lite

Rack Height

1U

Protection Type

Overload Protection

Input Current

15 A

Output Voltage

100 V AC

Plug/Connector Detail

2 x NEMA 5-15P

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping