MONITORED PDU 30A SNMP L5-30P 120V 16X5-20R 2U 12FT 3YR WTY

$575.89
Next

METERED ATS PDU 15A 1U 208V LCD 2 C14 12R C13 10FT CORDS 3YR WARR

$306.07
Next Product Image

SWITCHED ATS PDU 30A 2U 208V LCD 2 L6-30P 16R C13/2R C19/1R

$787.52

CyberPower PDU30SWHVT19ATNET 200 – 240 VAC 30A Switched ATS PDU – 19 Outlets, 10 ft, 2 x NEMA L6-30P, Horizontal, 2U, LCD, 3YR Warranty

SKU: PDU30SWHVT19ATNET UPC: 0649532610914 Brand: Cyberpower Condition: New Categories: , ,

Description

CyberPower PDU30SWHVT19ATNET 200 – 240 VAC 30A Switched ATS PDU – 19 Outlets, 10 ft, 2 x NEMA L6-30P, Horizontal, 2U, LCD, 3YR Warranty

The CyberPower PDU30SWHVT19ATNET, a 19-outlet (rear), 2U rackmount switched automatic transfer switch (ATS) power distribution unit (PDU), provides 200-240V 30A output. It distributes unfiltered electrical pass-through to to 19 receptacles–16 IEC-320 C13, 2 IEC-320 C19, and 1 NEMA L6-30R receptacles-from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.

The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the PDU. The switched outlet receptacles can be managed individually or collectively. The LCD panel provides local monitoring of the PDU and on/off control for the outlets. It can also be used to measure the electrical current (displayed in amperes) used by connected equipment. The LCD panel also shows input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions.

Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL and CSA certified by ETL, and Class A FCC-certified. A three-year warranty covers the PDU and connected equipment for as long as you own the product.

Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.

Outlet Switching
Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.

Automatic Transfer Switch
Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.

LCD Panel
Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.

Upgradeable Hardware & LCD Firmware
Are updatable to the latest versions by using the serial communication port and included cable.

Serial Communication Port & Cable
Used to update/upgrade the hardware and LCD firmware.

Environmental Sensor Option
Supports optional environment sensor (ENVIROSENSOR).

SNMP/HTTP Card
Included and installed, RMCARD203 provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.

Protocol Support
This Switched ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, and IPv4, IPv6, NTP, SMTP protocols.

Administrative Rights
Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.

Additional information

Product Type

PDU

Environmental Certification

RoHS

Management

HTTP TCP/IP UDP DHCP SNMP SNMPv3 IPv4 IPv6 NTP SMTP

Additional Information

Phase: Single PhaseFrequency: 50/60 HzLCD Displays: Amperage, Voltage, KW, Network Information, and Hardware/LCD FirmwareLED Indicators: Input, Output Load, Tx/Rx, LINK, OutletsUpgradeable Firmware: Yes – SNMP, HW, and LCD

Package Contents

PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P 2 x Mounting Brackets 24 x M4x8 Bracket Mounting Screws 6 x M5x12 Rack Mounting Screws 6 x Washers 2 x Cord Retention Trays 4 x M3x4 Cord Retention Tray Mounting Screws 30 x Cable Ties RJ45/DB9 Serial Port Connection Cable Jumper User Manual Registration Card CD 4 x IEC Socket Power Cord Stands 29 x M3x4 Screws 27 x Power Cord Retention Cable Clip 27 x Cable Ties

Certifications & Standards

UL60950-1 Certified by ETL (USA)CSA C22.2(Canada)FCC Class A

Country of Origin

China

Environmentally Friendly

Yes

Weight (Approximate)

16.76 lb

Product Series

Switched ATS PDU

Mount Type

Rack-mountable

Height

3.5"

Width

17.1"

Depth

9.3"

Output Voltage Range

200 V AC – 240 V AC

Receptacle Detail

16 x IEC 60320 C13

Marketing Information

The CyberPower PDU30SWHVT19ATNET, a 19-outlet (rear), 2U rackmount switched automatic transfer switch (ATS) power distribution unit (PDU), provides 200-240V 30A output. It distributes unfiltered electrical pass-through to to 19 receptacles–16 IEC-320 C13, 2 IEC-320 C19, and 1 NEMA L6-30R receptacles-from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the PDU. The switched outlet receptacles can be managed individually or collectively. The LCD panel provides local monitoring of the PDU and on/off control for the outlets. It can also be used to measure the electrical current (displayed in amperes) used by connected equipment. The LCD panel also shows input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions. Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL and CSA certified by ETL, and Class A FCC-certified. A three-year warranty covers the PDU and connected equipment for as long as you own the product. Power Distribution Delivers AC power to servers, equipment, and connected devices via a power distribution unit.Outlet Switching Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.Automatic Transfer Switch Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.LCD Panel Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.Upgradeable Hardware & LCD Firmware Are updatable to the latest versions by using the serial communication port and included cable.Serial Communication Port & Cable Used to update/upgrade the hardware and LCD firmware.Environmental Sensor Option Supports optional environment sensor (ENVIROSENSOR).SNMP/HTTP Card Included and installed, RMCARD203 provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.Protocol Support This Switched ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, and IPv4, IPv6, NTP, SMTP protocols.Administrative Rights Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.

Product Name

PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P

Input Voltage

230 V AC

Phase

Single Phase

Input Current

30 A

Rack Height

2U

Brand Name

CyberPower

Plug/Connector Type

NEMA L6-30P

Input Voltage Range

200 V AC – 240 V AC

Cord Length

10 ft

Receptacle Type

NEMA L6-30R

Product Model

PDU30SWHVT19ATNET

Product Family

Switched ATS PDU

Energy Star

No

PDU Type

Switched Auto Transfer Switch

Manufacturer Part Number

PDU30SWHVT19ATNET

Manufacturer Website Address

http://www.cyberpowersystems.com

Manufacturer

CyberPower Systems, Inc

Plug/Connector Detail

2 x NEMA L6-30P

0
    0