Free Shipping
Free Returns
Easy Payments
Sign up For our Blog
Trade in Welcome
Buy or Lease
Previous
Previous Product Image

UPS SMART INT 2200VA 1600W USB TOWER 230V9OUTLETS RS232

$843.00
Next

3-PHASE PDU SWITCHED 25.2KW 240V 12 C13 12 C19 60A IEC309 TAA

$1,382.76
Next Product Image

UPS SMART ONLINE 6KVA 6KW 5URM UNITY PF BYPASS PDU TRANSFORMER

$5,085.12

Tripp Lite UPS Smart Online 6kVA 6kW Unity Power Factor ByPass PDU Transformer 5URM – 3U Rack/Tower – 3 Hour Recharge – 3 Minute Stand-by – 230 V AC Input – 120 V AC, 208 V AC, 240 V AC Output – 4 x NEMA L6-20R, 2 x NEMA L6-30R, 8 x NEMA 5-20R, 4 x NEMA 5-15R, Hardwired – TAA Compliant

SKU: SU6KRT3UTFMB UPC: 0037332241535 Brand: Tripp Lite Condition: New Categories: , ,

Description

Tripp Lite UPS Smart Online 6kVA 6kW Unity Power Factor ByPass PDU Transformer 5URM – 3U Rack/Tower – 3 Hour Recharge – 3 Minute Stand-by – 230 V AC Input – 120 V AC, 208 V AC, 240 V AC Output – 4 x NEMA L6-20R, 2 x NEMA L6-30R, 8 x NEMA 5-20R, 4 x NEMA 5-15R, Hardwired – TAA Compliant

Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss

Tripp Lite’s SU6KRT3UTFMB Unity Power Factor UPS system with Maintenance Bypass Switch and Detachable Bypass PDU protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Unity Power Factor design enables full 6000VA / 6000W output capacity when used with hardwire 208/240V input power. Optional L6-30P input cord included (output de-rates to 5600W with 240V input & 4800W with 208V input when the L6-30P cord is used). In double-conversion mode, this UPS system maintains perfect output by continuously converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with ±1% voltage regulation and zero transfer time between online and battery modes. Featuring true on-line, double-conversion operation, Tripp Lite’s SmartOnline® SU6KRT3UTFMB provides the highest level of UPS power protection for critical server, network and telecom equipment.

High Availability Configuration Offers Reliable, Expandable Battery Backup

Included Maintenance Bypass Switch is mounted on a detachable Bypass PDU that securely mounts to the rear-rails of a 4 post rack enclosure and remains safely in-place powering your equipment during UPS maintenance. The UPS connects to the Bypass PDU using a sophisticated blind-mate connector set with self-aligning guide-pins to ensure safe and reliable whole-UPS replacement with zero downtime for connected equipment. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The internal battery set provides 8.5 minutes of support at half load and 3 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. Advanced temperature-controlled battery charge management system provides efficient recharge and enhanced battery lifespan. For mission-critical applications demanding continuous uptime, the 6kVA UPS can provide expandable runtime with optional BP192V12RT3US external battery pack (sold separately). Battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries.

Economy Mode Helps the Environment and Your Cash Flow

Operates with >98% full-load efficiency in optional economy mode significantly reducing BTU heat output and operating energy costs.

Intuitive Front-Panel Interface offers Convenient Monitoring

Front-panel LEDs indicate line power, AC output, On-battery mode, and Fault conditions. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration.

Pre-installed WEBCARDLXMINI Network Interface Offers 24/7 Access

Pre-installed Java-free HTML5-based WEBCARDLXMINI interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports with included cabling enable data-saving unattended shutdown of connected systems when used with Tripp Lite’s free downloadable PowerAlert® software.

Additional information

Application/Usage

Mission Critical Equipment

Country of Origin

Taiwan

Manufacturer

Tripp Lite by Eaton

Product Model

SU6KRT3UTFMB

Product Name

SmartOnline SU6KRT3UTFMB 6kVA Rack/Tower UPS

Product Line

SmartOnline

Marketing Information

Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss Tripp Lite's SU6KRT3UTFMB Unity Power Factor UPS system with Maintenance Bypass Switch and Detachable Bypass PDU protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Unity Power Factor design enables full 6000VA / 6000W output capacity when used with hardwire 208/240V input power. Optional L6-30P input cord included (output de-rates to 5600W with 240V input & 4800W with 208V input when the L6-30P cord is used). In double-conversion mode, this UPS system maintains perfect output by continuously converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with ±1% voltage regulation and zero transfer time between online and battery modes. Featuring true on-line, double-conversion operation, Tripp Lite's SmartOnline® SU6KRT3UTFMB provides the highest level of UPS power protection for critical server, network and telecom equipment. High Availability Configuration Offers Reliable, Expandable Battery Backup Included Maintenance Bypass Switch is mounted on a detachable Bypass PDU that securely mounts to the rear-rails of a 4 post rack enclosure and remains safely in-place powering your equipment during UPS maintenance. The UPS connects to the Bypass PDU using a sophisticated blind-mate connector set with self-aligning guide-pins to ensure safe and reliable whole-UPS replacement with zero downtime for connected equipment. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The internal battery set provides 8.5 minutes of support at half load and 3 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. Advanced temperature-controlled battery charge management system provides efficient recharge and enhanced battery lifespan. For mission-critical applications demanding continuous uptime, the 6kVA UPS can provide expandable runtime with optional BP192V12RT3US external battery pack (sold separately). Battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries. Economy Mode Helps the Environment and Your Cash Flow Operates with >98% full-load efficiency in optional economy mode significantly reducing BTU heat output and operating energy costs. Intuitive Front-Panel Interface offers Convenient Monitoring Front-panel LEDs indicate line power, AC output, On-battery mode, and Fault conditions. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration. Pre-installed WEBCARDLXMINI Network Interface Offers 24/7 Access Pre-installed Java-free HTML5-based WEBCARDLXMINI interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports with included cabling enable data-saving unattended shutdown of connected systems when used with Tripp Lite's free downloadable PowerAlert® software.

Serial Port

Yes

EPO Port

Yes

USB (HID Compliant) Port

Yes

Alarm

UPS Power Condition

Package Contents

SmartOnline SU6KRT3UTFMB 6kVA Rack/Tower UPS Pre-installed WEBCARDLXMINI Network Management Card Detachable Bypass PDU Step-down Transformer 2 x Hardwire Strain Reliefs USB Cable RS-232 Cable L6-30P Power Cable Rack-mounting Hardware Owner's Manual

Software Included

PowerAlert

Environmentally Friendly

Yes

Manufacturer Part Number

SU6KRT3UTFMB

Environmental Certification

RoHS

Weight (Approximate)

125.20 lb

Height

8.7"

Width

17.5"

Depth

35.5"

Output Voltage

120 V AC

Surge Energy Rating

1680 J

Output Frequency

60 Hz

Input Frequency

60 Hz

Overload Protection

Yes

EMI/RFI Noise Filter

Yes

Transfer Time

0 ns

Manufacturer Website Address

http://www.tripplite.com

Maximum Operating Elevation

6562 ft

Battery Chemistry

Lead Acid

Product Family

SmartOnline

Product Type

Double Conversion Online UPS

Hot Swappable

Yes

Input Voltage

230 V AC

Form Factor

Rack/Tower

Network Management

SNMP/Telnet/SSH

Waveform Type

Pure Sine Wave

Rack Height

3U

Brand Name

Tripp Lite

Plug/Connector Type

Hardwired

Phase

Single Phase

Receptacle Type

NEMA 5-20R

Backup/Run Time (Half Load)

8.50 Minute

Maximum Operating Temperature

104°F (40°C)

Backup/Run Time (Full Load)

3 Minute

Load Capacity (VA)

6000 VA

Replaceable Battery

Yes

TAA Compliant

Yes

Energy Star

Yes

Load Capacity (W)

6000 W

Battery Characteristics

Valve-regulated

DC System Voltage

192 V DC

Typical Battery Recharge Time

3 Hour

Status Indicators

Front Panel LCD Display Selectable LCD display: Escape Page Up Page Down Enter and Power buttons enable UPS control Detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual) 4 front-panel LEDs: AC input AC output Battery mode Fault conditions

Sound Emission

67 dB

Thermal Dissipation

380.99 W

Receptacle Detail

4 x NEMA 5-15R

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping